===== Version 3.10.367 (23 November 2026) ===== ==== Manufacturer Item Pool – Duplicate EANs in Subscriptions ==== If manufacturer item pools containing the same EANs are stored in multiple locations within a node, this used to result in an error when an item subscription was performed. This has been rectified. The subscription now returns EANs that appear more than once. ==== SFTP Server Receive Channel – Partner Assignment ==== The [[en:kommunikation:kanal:sftpserverreceive|SFTP Server Receive Channel]] assigns the partner to messages created from uploaded files when both of the following conditions are met: * The client logs in using an SFTP server address. * Partner detection is enabled in the ''ChannelReceiver''. ==== ExcelImporter Job Step – Filter by Error State ==== With the new **Error state <** option, the [[en:prozessdefinition:jobs:jobsteps:allgemein:excelimporter|ExcelImporter]] processes only messages whose error state is below the specified value. ==== eBiss Compact – Configurable Time Intervals ==== Users with an eBiss Compact license can now configure the time intervals for the [[en:prozessdefinition:automatisierungen:zeitgesteuert|Scheduled Event Listener]]. ==== Type Libraries – Duplicate Class Names ==== Generating an assembly from a [[en:programmierung:typbibliotheken:start|type library]] could produce duplicate class names when different structural elements in that library each contained a child element with the same name, such as ''Item''. This issue has been fixed. ==== eBiss API – Access to Job Variables via IEnvironment ==== The ''IEnvironment'' interface in the eBiss API now provides the methods ''SetJobVariable'' and ''GetJobVariable''. Plug-ins can use these methods to set and read job variables. ==== Port Event Listener – Maintenance Interface ==== Previously, a call to the [[en:howtos:maintenanceinterface|maintenance interface]] caused the [[en:prozessdefinition:automatisierungen:port|Port Event Listener]] to start a job and create a process instance. When the maintenance interface is enabled, the Port Event Listener now checks the incoming connection before starting a job. It skips the job in either of the following cases: * The listener recognizes the incoming data as a maintenance interface request. * The remote endpoint closes the connection without sending any data during the check, which lasts up to 50 milliseconds. This can occur during a TCP health check. ==== File System Event Listener – Minimum Time Since Last File Change ==== The new **Unchanged for (min.)** setting specifies how many minutes must elapse after a file was last modified before the [[en:prozessdefinition:automatisierungen:file|File System Event Listener]] reports it. When a value is set, the File System Receive Channel processes only the files reported by the listener. ==== Messages Larger Than 2 GB – Message Size Display ==== An integer overflow in the size calculation could cause messages larger than 2 GB to appear to have a negative size. The message size is now displayed correctly. ==== XML Reader – Empty Element with the Same Name as Its Parent ==== The XML reader could report an error or skip elements when an empty element appeared immediately before the closing tag of a parent element with the same name. In the following example, the empty ''KonditionText'' element appears immediately before its parent's closing tag: ... A unit test reproduced the issue, and the XML reader now handles this case correctly. ==== eBiss Pranke ORM – Optimised memory release ==== The Pranke ORM layer has been optimised and now releases references earlier. This allows the memory being used by eBiss to be released sooner.