Version 3.10.367 (23 November 2026)

Manufacturer Item Pool – Duplicate EANs in Subscriptions

If manufacturer item pools containing the same EANs are stored in multiple locations within a node, this used to result in an error when an item subscription was performed. This has been rectified. The subscription now returns EANs that appear more than once.

SFTP Server Receive Channel – Partner Assignment

The SFTP Server Receive Channel assigns the partner to messages created from uploaded files when both of the following conditions are met:

ExcelImporter Job Step – Filter by Error State

With the new Error state < option, the ExcelImporter processes only messages whose error state is below the specified value.

eBiss Compact – Configurable Time Intervals

Users with an eBiss Compact license can now configure the time intervals for the Scheduled Event Listener.

Type Libraries – Duplicate Class Names

Generating an assembly from a type library could produce duplicate class names when different structural elements in that library each contained a child element with the same name, such as Item. This issue has been fixed.

eBiss API – Access to Job Variables via IEnvironment

The IEnvironment interface in the eBiss API now provides the methods SetJobVariable and GetJobVariable. Plug-ins can use these methods to set and read job variables.

Port Event Listener – Maintenance Interface

Previously, a call to the maintenance interface caused the Port Event Listener to start a job and create a process instance.

When the maintenance interface is enabled, the Port Event Listener now checks the incoming connection before starting a job. It skips the job in either of the following cases:

File System Event Listener – Minimum Time Since Last File Change

The new Unchanged for (min.) setting specifies how many minutes must elapse after a file was last modified before the File System Event Listener reports it. When a value is set, the File System Receive Channel processes only the files reported by the listener.

Messages Larger Than 2 GB – Message Size Display

An integer overflow in the size calculation could cause messages larger than 2 GB to appear to have a negative size. The message size is now displayed correctly.

XML Reader – Empty Element with the Same Name as Its Parent

The XML reader could report an error or skip elements when an empty element appeared immediately before the closing tag of a parent element with the same name. In the following example, the empty KonditionText element appears immediately before its parent's closing tag:

<KonditionText>
    ...
    <KonditionQualifier/>
    <KonditionText/>
</KonditionText>

A unit test reproduced the issue, and the XML reader now handles this case correctly.

eBiss Pranke ORM – Optimised memory release

The Pranke ORM layer has been optimised and now releases references earlier. This allows the memory being used by eBiss to be released sooner.